X-T20 Transmitter
The tension transducer converts millivolt output signal of tension sensors into analog signal or digital signal in real time, and provide closed loop control for PLC, servo drive, IPC and other control systems. The transducer adopts guide rail type installation. It can display realtime tension value and calibration parameters can be set through hand-held device.
Category
X-T20 Transmitter
Features
●Analog input/output: 2 Channel / 1 Channel
●Switching input/output: 2 Channel / 2 Channel
●Reset: switch input, clear command,automatic zero clearing when power.
●Analog transmission: 0-10V,±10V,4-20mA,1-10V
●Digital output: RS232,RS485
●Protocol: MODBUS-RTU,TC-ASCII
●Analog transmission range: -100% – +100%FS
Description
The tension transducer converts millivolt output signal of tension sensors into analog signal or digital signal in real time, and provide closed loop control for PLC, servo drive, IPC and other control systems. The transducer adopts guide rail type installation. It can display real time tension value and calibration parameters can be set through hand-held device. It is convenient for rapid tension reset and alarm output with switching input and output nodes.The module supports single/double channel signal input and analog variable output. It can complete the tension closed loop transmission of winding and unwinding
Technical Parameter
Power supply | DC24V/5W | AD resolution | 24 bit |
Sensor’s supply voltage | 5VDC,200mA | Sampling rate | 600-4800 Times/Sec. |
Input signal range | 0-20mV | Transmitting speed | =Sampling rate |
Non-linearity | 0.01%F.S. | Switch output type & capacity | NPN/PNP,500mA |
Accuracy | 0.5%F.S. | Switch input type | NPN |
Dimensions
Selection
Model | Input signal | Accurancy | Power supply | Signal output | Special requirements |
XJC-T200F | M:mV
DM double:mV
|
B:0.05%
D:0.1%-0.5% |
D:24VDC | R2: RS232,
R4: RS485, V:0-10V OR ±10V A:4-20mA V2:double 0-10V OR ±10V |
Y/N |